12V/24V Relay Voltage Triggered Load Controller "W/Delay" 1URVTLC-1224-B V2 NEW

$ 26.39

Availability: 101 in stock
  • Voltage: 12V/24V
  • Voltage Input: 12V/24V
  • Country/Region of Manufacture: United States
  • Model: 1URVTLC-1224-B
  • Condition: New
  • Current Output: 1A Max
  • Recommended Environment: Indoor
  • Features: LCD Display
  • All returns accepted: ReturnsNotAccepted
  • MPN: 1URVTLC-1224-B
  • Type: Load Controller
  • Brand: WindAndSunPower.com
  • Voltage Output: 12V/24V

    Description

    Due to EBAY policy changes, I will be shipping once payment clears.
    NEW V2 DUMP CONTROLLERS – EVOLVED ($
    7
    9.95 SRP)
    1 UNIVERSAL RELAY VOLTAGE TRIGGERED LOAD CONTROLLER “B Model” V2
    MODEL 1URVTLC-1224-B 12V/24V
    V2
    V2 Extended Voltage Range for 12V & 24V Lead Acid Batteries, 3S, 4S, 6S and 7S Lithium Ion Battery Packs
    For both EMR’s
    (ElectroMechanical Relays)
    and SSR’s
    (Solid State Relays)
    International First Class Mail only:
    If you don't receive your item within 3 to 4 weeks please contact your postal service with the tracking/customs info. It is out of my hands once a First Class Package leaves the US. Also, it can be extremely slow to some countries (Russia, Italy, Mexico, Philippines, S. Africa, Greece, etc). With possible delays of 2 to 3 months or more.
    I also tested one of the so called 12V
    440 Amp 6 Terminal Solenoids
    (
    Sold as
    Relays).
    It
    's
    coil
    had a
    n
    on current of less than 700ma and worked fine with my controllers.
    Use
    CAUTION
    a
    s different manufactures may differ in specs on these, you should measure the coils ON current draw to assure it's less than 1 Amp. Also if using in a 24V system, be sure to get one with a 24V coil as these output the battery voltage to activate the relays.
    DESCRIPTION
    The “Universal Relay”
    Voltage Triggered Load Controllers
    are
    low cost, Microprocessor controlled Diversion
    Load Switching
    type controller
    s
    designed for the
    System Designer or
    DIY
    (
    D
    o
    I
    t
    Y
    ourselfer)
    . It is designed to switch up to
    8
    conventional automotive style electromechanical relays
    (EMR)
    directly with up to
    1.25A
    @ 40C
    total coil current draw with up to
    32
    0A power handling capability.
    It is theoretically able to directly switch up to
    50
    SSR's at 25ma each
    (untested)
    . If using just 40 amp SSR's that adds up to a potential
    2000
    A
    (
    4000
    A using 80 amp SSR's)
    power handling capability.
    To keep cost down, this controller was designed for the
    System Designer or
    DIY
    (Do It Yourselfer)
    and is the
    BOARD ONLY
    and does
    not
    include an enclosure. It can be mounted directly on a wall in
    an area
    protected from the environment or in
    an
    Optional
    or
    user supplied
    enclosure.
    Please Download and read the Manual
    Thoroughly
    before purchasing
    at
    WindAndSunPower
    (
    D0T
    ) com
    POSSIBLE USES
    Automate Devices to Turn On and Off at Specific Voltages
    LVD – Low Voltage Disconnect / HVC – High Voltage Connect
    HVD – High Voltage Disconnect / LVC – Low Voltage Connect
    Diversion/Dump Controller
    Automate Ventilation Fans
    Automate Battery Chargers
    Automate
    “Some Types”
    of Generators with Remote Start Functions
    Alarms
    Etc, etc
    FEATURES
    The ability to Directly Switch up to
    8
    Electromechanical or
    50
    + DC-DC Solid State Relays
    12V
    Mode
    Individual
    Adjustable
    On-Off Set-point
    s
    (
    7
    .5
    to 1
    7.0
    Volts
    in 0.
    1
    V increments
    )
    24V
    Mode
    Individual
    Adjustable On-Off Set-point
    s
    (
    15.
    0
    to
    3
    1.
    5
    Volts
    in 0.
    1
    V increments
    )
    Seconds Mode
    Individual
    On-Off Adjustable Set-point
    Delays (0 to 120 Seconds)
    Minutes Mode
    Individual
    On-Off Adjustable Set-point
    Delays (0 to 120 Minutes)
    Extremely Low Power Consumption
    (

    3
    0
    ma
    max
    )
    2-Line Backlit LCD Display with settable brightness or auto off
    Accurate Volt Meter/Tracking
    (
    3
    decimal points
    resolution
    ±
    0.
    05
    %
    +
    5
    digits
    or less typically
    )
    16
    Mhz 8-Bit Microcontroller
    Latest SMT
    (Surface Mount Technology)
    for Compact Size and Improved Performance
    Self Resetting Fuse
    Relay Powered/Active LED Indicator
    Test Button
    Reverse Polarity Protection
    Over Voltage Protection
    Over Current Protection
    Transient/Lightning/Surge Protection
    BASIC OPERATING PRINCIPLE
    Basic operation principle is quite simple. The Microcontroller constantly monitors the battery voltage. When battery voltage meets the specific criteria, the Microcontroller activates or deactivates the LED’s and external relays.
    (Example
    1
    – “
    OFF
    <13.0V
    40S
    ”. When the Battery Voltage Drops Below 13.0V
    it will start a 40 Second Countdown. If the Battery Voltage remains Below 13.0V for the Full 40 Seconds, Then the controller will turn OFF the Relay (Output). But, if the Battery voltage Rises Above 13.0V Before the timer runs out, the timer will reset
    and the Relay Output will remain O
    N
    ).
    (Example
    2
    – “
    O
    N
    >
    13.0V
    40S
    ”. When the Battery Voltage
    Rises Above
    13.0V
    it will start a 40 Second Countdown. If the Battery Voltage remains
    Above
    13.0V for the Full 40 Seconds, Then the controller will turn O
    N
    the Relay (Output). But, if the Battery voltage
    Drops Below
    13.0V Before the timer runs out, the timer will reset
    and the Relay Output will remain OFF
    ).
    SPECIFICATIONS
    Min. Operating Volts
    7VDC
    Max. Operating Volts
    Volts Max.
    32VDC
    35VDC
    Nominal Operation Voltage
    12VDC or
    24VDC
    Relay Connectors Output Voltage
    =
    Battery Voltage
    Max. Power Used
    by Controller

    15ma max
    Power Sunk @ Ambient Temp.
    -1.25A Max. @ 40C
    -1.00A Max. @ 60C
    12V Voltage Adjustment Range
    7.5 to 17.0 Volts in 0.1V increments
    24V Voltage Adjustment Range
    15
    .0
    to
    3
    1
    .
    5
    Volts in 0.
    1
    V increments
    Seconds Adjustment Range
    0 to 120 Seconds
    Minutes Adjustment Range
    0 to 120 Minutes
    LCD Accuracy
    Battery Voltage
    3
    decimal points
    resolution
    ±
    0.
    05
    %
    +
    5
    digits
    or less @ 23C
    Internal
    Battery Voltage Tracking
    ±
    0.
    05
    %
    +
    5
    digits
    or less @ 23C
    Automotive style ElectroMechanical Relays
    1 up to 8
    12 or 24VDC Coil
    @ 160ma Per Coil
    Solid State Relays
    DC-DC 1 up to 50?

    10ms On or less

    10ms Off or less
    Operating Temp.
    Storage Temp.
    -20
    °
    C to
    6
    0
    °
    C
    -50
    °
    C to 150
    °
    C
    Dimensions
    100 mm x 50 mm
    (3.93 in. x 1.96 in.)
    Specifications subject to change without notice.
    Made in USA-Components Made in Rest of World
    WARRANTY:
    WindAndSunPower (D0T) com
    Model
    1URVTLC-1224-B
    is warranted to be free of defects in material and workmanship for three years from the date of purchase. Failure to provide correct installation, operation or care for this product, in accordance with the instruction manual, will void the warranty. Product liability shall be limited to repair or replacement at the discretion of the manufacturer. The manufacturer is not responsible for the labor or other charges necessitated by the removal, transportation, or re-installation of any defective product. Warranty does not cover damage due to, mishandling, abusive conditions, lightning or exposure to weather. No specific claim of merchantability shall be assumed or implied beyond what is printed in this manual. No liability shall exist from circumstances arising from the inability to use this product, or it’s inappropriateness for any specific purpose. In all cases it shall be the responsibility of the customer to insure a safe installation in compliance with local, state and national electrical codes.
    COPYRIGHT© 2010-201
    8
    Jeff Mason
    WindAndSunPower (D0T) com
    All Rights Reserved